HIMA H41Q-HRS B4237-2 High-Availability Safety-Related System Rack
- Product Code: H41Q-HRS B4237-2
 - Availability: In Stock
 
HIMA H41Q-HRS B4237-2
High-Availability Safety-Related System Rack
Product Overview
The HIMA H41Q-HRS B4237-2 is a compact Programmable Electronic Safety (PES) system designed for high and highest availability applications in the process industry. It is TÜV-tested and meets the requirements of Safety Integrity Level (SIL) 3 according to IEC 61508, making it suitable for safety-critical applications that demand reliable and precise control signals.
As part of HIMA's HiQuad family of systems, this product utilizes a QMR-quadruple modular redundant design, featuring four microprocessors integrated on the same Control Unit (CU) module, with two identical CU modules forming the central control unit. This physically separated redundant structure eliminates the risk of common-cause failures.
Key Features
Redundant Design
- Redundant central modules for increased safety
 - Redundant I/O bus for fault tolerance
 - Quadruple Modular Redundant (QMR) architecture
 
High Availability
- Hot-standby capability for uninterrupted operation
 - No single point of failure
 - Automatic switchover in case of component failure
 
Diagnostics & Maintenance
- Integrated diagnostics for easier maintenance
 - Online configuration and modification
 - Self-monitoring functions with status indication
 
Flexibility & Scalability
- Modular design for easy scalability
 - Support for various communication protocols
 - Flexible configuration options for different applications
 
Technical Specifications
| Power Supply | 24 VDC or 48 VDC | 
| I/O Capacity | Up to 13 I/O modules | 
| Dimensions | 19 inches (483 mm) x 5U (224 mm) x 236 mm | 
| Weight | Approx. 20 kg | 
| Communication | PROFIBUS DP, PROFINET, Modbus TCP/IP | 
| Safety Rating | SIL 3 according to IEC 61508 | 
| Certifications | TÜV, CE, UL, ATEX | 
| Environmental Rating | IP20 | 
Applications
                Process Industry
Chemical, petrochemical, oil and gas plants requiring high safety standards
                Power Generation
Nuclear, thermal, and hydroelectric power plants for safety-critical control
                Railway Systems
Train control systems, signaling, and platform safety applications
                Marine Industry
Shipboard safety systems and critical process control
System Architecture
            HIMA H41Q-HRS B4237-2 System Architecture with Redundant Modules
Compliance & Certifications
HIMA H41Q-HRS B4237-2 | Safety-Related System Rack | Product Documentation
© 2025 HIMA Paul Hildebrandt GmbH & Co. KG | All rights reserved